Ground Heater E2200 |

- Thaw ground - quickly, easily, and economically
- 2,200-4,400 sq. ft. with standard equipment*
- up to 4,400 sq. ft. in ½ the time with accessories
Varies based on soil conditions. Complete a Ground Heaters' Thaw Cost Plan.
- Cure concrete - in cold weather with confidence
- up to 4,400 sq. ft. with standard equipment
- up to 13,200 sq. ft. with accessories
Varies based on application. Complete a Ground Heaters' Cure Cost Plan.
- Prevent Frost - large areas, very economically
- up to 6,600 sq. ft. standard
- up to 19,800 sq. ft. with accessories
- Heat workspace - dry heat and fuel efficient
- up to 360,000 cu. ft. with accessories
Varies based on application. Ask your dealer for a Air Heat Cost Estimate.
- Up to 130 hours run-time
- Engineered for reliable, trouble-free start
- Easy to operate
- Economical
- Dependable
- Built Tundra Tough™
- 87% heater efficiency - highest in the industry
Thaw and cure large areas:
- Thaw up to 1 foot deep/day(dependent on conditions)
- Set, finish and cure concrete like it's summer
- Protect newly poured concrete from frost
Dimensions and capacities (no generator/with generator)
| Length | 167" |
| Width | 72" |
| Height | 88" |
| Ground clearance | 12" |
| Weight w/o fuel | 4,715/5,240 lbs |
| Weight with fuel | 5,772/6,297 lbs |
| Fuel capacity | 150 US GAL |
| Heat Transfer Fluid | 95 US GAL |
| Pumps, 265 gph positive displacement | 2 |
| Hose (2 x 1100 ft) | 2,200 ft |
| Hose reels | 1 |
| Hose rewind | 120V AC electric, w/ 12V DC clutch |
| Circulation loops | 2 |
| Tires | ST235/80R16 |
| Hitch | pintle or 25/16" ball |
Performance
| Brakes | 12V DC electric |
| Tie Downs (for transport) | 4 |
| Ground fault interrupt | yes |
| Main circuit breakers | 2 |
| Burner motor thermal protection | manual reset |
| Burner Ignition | electronic |
| High temperature shutdown | yes |
| No-flame shutdown | yes |
| Low fluid shutdown/warning light | yes |
| Vented closed loop circulation | yes |
| Hydronic heater operating pressure | 0 psi |
| Temperature gauges | 5 |
| Pressure gauges | 2 |
| Interior light, 120V AC | 1 |
Safety
| Heater, gross output | 252,000 BTU/H |
| Heater, net output | 220,000 BTU/H |
| Heater, efficiency | 87% |
| Temperature controller | digital |
| Fuel consumption at full load | 1.80/2.20 US GPH |
| Fuel requirement | winter blend diesel |
| Run time | up to 130 hours |
| Electrical requirement | 2 x 20 amps x 120V AC |
| Normal operating temp | 100°F - 180°F |
| Normal hose operating press. | 70-90 psi |
Performance
| HTF flow rate per loop | 265 US GPH |
| Thawing capacity (std equipment) | 2,200-4,400 sq ft |
| Thawing capacity (w/ accessories) | up to 4,400 sq ft |
| Curing capacity (std equipment) | 4,400 sq ft |
| Curing capacity (w/ accessories) | up to 13,200 sq ft |
| Frost Prevention (std equipment) | up to 6,600 sq ft |
| Frost Prevention (w/ accessories) | up to 19,800 sq ft |
| Air heat capacity (w/ accessories) | 360,000 sq ft |
| Performance monitoring system | yes |